FITPIPE FITTINGS |
|
The simple but effective engineering
principle of the Fitpipe Fitting is the foundation of the most
versatile pipe connection system available. There are many
variations of fitting to suit wide-ranging applications, providing
the versatility to achieve virtually any structural configuration.
Fitpipe fittings are ductile iron castings manufactured to the
requirements of ASTM A47-77-32510. A range of fittings to suit eight
sizes of pipe is available. A simple hexagon key is the only tool
required to create a strong, rigid joint. A recessed set screw,
tightened by the hexagon key, firmly locks the pipe into the
fitting.
A Fitpipe fitting (size 5 to 9) can support an axial load of *2000
lbs. per set screw with the set screw tightened to a torque of 29
lbs. ft. This is normally obtained when the screw is fully tightened
using a ratchet wrench.
|
SPECIFYING FITPIPE FITTINGS
The information on fittings in this site is
comprehensive, and because of the coding system we have
adopted, easy to use.
Diagrams are shown for each fitting showing entry of
tube/pipe, a table of dimensions and a definition of use
adjacent to its appropriate Type number (10, 15, 20, 25
etc.).
Alongside the Type number is a code (4, 5, 6, 7, etc.)
relating to the outside diameter of the tube/pipe for
which the Fitpipe had been designed. The relationship
between the Fitpipe tube/pipe reference and standard
tube/pipe outside diameter is explained in the
aforementioned chart.
Example: (1) A 10-7 is a Type 10 Fitpipe fitting with
both sockets designed to accept a tube/pipe that has an
outside diameter of 42.4mm or 1 11/16" (1 1/4" Nominal
Pipe Size). (2) A 25-9 is a Type 25 Fitpipe fitting with
all three sockets designed to accept a tube/pipe that
has an outside diameter of 60.9mm or 2 3/8" (2" N.P.S.).
Where more than one tube/pipe reference is shown
alongside a particular Type number, it indicates that
the individual sockets are designed to accept different
sizes of tube/pipe. In a multi-digit code number the
first figure relates to the 'A' socket and the second to
the 'B' socket. Example (3) A 45-76 is a Type 45 Fitpipe
fitting with 'A' socket accepting a tube/pipe that has
an outside diameter of 42.4mm or 1 11/16", and a 'B'
socket accepting a tube/pipe that has an outside
diameter of 33.7mm or 1 11/32".
While Fitpipe can give a general guidance relating to
the use of each Fitpipe fitting detailed in this site,
the nature of the product means that the ultimate
responsibility for selecting the correct fitting for an
application must lie with the customer.
The customer should also ensure that the existing
structure to which the Fitpipe construction is being
secured, is of sufficient strength to support both the
self weight of the Fitpipe construction and the imposed
loads applied, including wind loads, snow loads, and any
other superimposed loads.
BEAM
LOAD TABLE
For uneven load distributions or single
spans, the required pipe size must be
determined by standard bending moment
calculations assuming a Fitpipe joint to
give a simply supported beam. The table
shown below gives an indication only of the
safe load uniformly distributed, in lbs.,
that may be carried per shelf consisting of
front and back tubes when used as continuous
beams. Recommended set screw torque:
29lbs./ft.
At loads greater than 2023 lbs.,
consideration must be given to set-screw
slip.
|

|
|
|
BEAM LOAD
TABLE ( lb ) |
|
FITPIPE FITTING |
Size 5 |
Size 6 |
Size 7 |
Size 8 |
Size 9 |
|
|
SIZE OF PIPE |
¾" N.B. |
1"
N.B. |
1¼" N.B. |
1½" N.B. |
2" N.B. |
|
|
GRADE OF
MATERIAL |
SCH. 40 |
SCH. 40 |
SCH. 40 |
SCH. 40 |
SCH. 40 |
|
|
SPAN |
|
SPAN |
|
1' |
1658 |
3123 |
5516 |
7669 |
13180 |
1' |
|
2' |
829 |
1562 |
2758 |
3834 |
6590 |
2' |
|
3' |
553 |
1041 |
1838 |
2556 |
4393 |
3' |
|
3' 6" |
474 |
892 |
1576 |
2191 |
3766 |
3' 6" |
|
4' |
414 |
781 |
1379 |
1917 |
3295 |
4' |
|
4' 6" |
368 |
694 |
1226 |
1704 |
2929 |
4' 6" |
|
5' |
332 |
625 |
1103 |
1534 |
2636 |
5' |
|
5' 6" |
302 |
568 |
1003 |
1394 |
2396 |
5' 6" |
|
6' |
277 |
520 |
919 |
1278 |
2197 |
6' |
|
6' 6" |
255 |
481 |
849 |
1180 |
2028 |
6' 6" |
|
7' |
237 |
446 |
788 |
1096 |
1883 |
7' |
|
7' 6" |
221 |
417 |
735 |
1023 |
1757 |
7' 6" |
|
8' |
207 |
390 |
690 |
959 |
1648 |
8' |
|
9' |
184 |
347 |
613 |
852 |
1464 |
9' |
|
10' |
166 |
313 |
551 |
767 |
1318 |
10' |
|
Table reflects a safety factor
of 1.67:1
|
|
|
| |
|
|
UPRIGHT LOAD TABLE
This table gives an indication only of the safe
load, in lbs., that may be carried between the
above restraints by single Schedule 40 pipe,
30000 PSI, when used as uprights. Loads listed
under 'A' columns refer to those loads that are
obtainable according to schematic 'B'. Schematic
'B' details a racking system that is
mechanically affixed to the surface on which it
stands, whereas Schematic 'A' details a
free-standing racking system. Recommended screw
torque: 29 lbs./ft. |
 |
|
|
UPRIGHT LOAD TABLE ( lb
) |
|
Fitpipe
FITTING |
Size 5 |
Size 6 |
Size 7 |
Size 8 |
Size 9 |
|
|
SIZE OF
PIPE |
¾" N.B. |
1" N.B. |
1¼" N.B. |
1½" N.B. |
2" N.B. |
|
|
MATERIAL
GRADE |
SCH. 40 |
SCH. 40 |
SCH. 40 |
SCH. 40 |
SCH. 40 |
|
|
Length |
A |
B |
A |
B |
A |
B |
A |
B |
A |
B |
Length |
|
1' 0" |
1868 |
2045 |
3243 |
3390 |
4445 |
4635 |
5238 |
5403 |
7738 |
7975 |
1' 0" |
|
1' 3" |
1633 |
1855 |
2958 |
3183 |
4213 |
4445 |
4955 |
5235 |
7398 |
7635 |
1' 3" |
|
1' 6" |
1420 |
1633 |
2673 |
2958 |
3875 |
4213 |
4650 |
4955 |
7160 |
7443 |
1' 6" |
|
1' 9" |
1213 |
1493 |
2375 |
2705 |
3630 |
3948 |
4395 |
4730 |
6785 |
7160 |
1' 9" |
|
2' 0" |
995 |
1283 |
2108 |
2480 |
3335 |
3715 |
4138 |
4500 |
6448 |
6843 |
2' 0" |
|
2' 3" |
840 |
1058 |
1813 |
2245 |
3048 |
3470 |
3883 |
4268 |
6210 |
6685 |
2' 3" |
|
2' 6" |
700 |
953 |
1583 |
2020 |
2753 |
3273 |
3570 |
4003 |
5848 |
6355 |
2' 6" |
|
2' 9" |
603 |
823 |
1395 |
1780 |
2505 |
2993 |
3243 |
3730 |
5575 |
6063 |
2' 9" |
|
3' 0" |
N/A |
700 |
1220 |
1583 |
2170 |
2703 |
2985 |
3523 |
5180 |
5835 |
3' 0" |
|
3' 3" |
N/A |
635 |
1078 |
1435 |
1993 |
2563 |
2698 |
3283 |
4863 |
5520 |
3' 3" |
|
|
|
|
948 |
1288 |
1810 |
2283 |
2418 |
3083 |
4525 |
5270 |
3' 6" |
|
|
|
|
N/A |
1160 |
1643 |
2085 |
2250 |
2858 |
4218 |
4978 |
3' 9" |
|
|
|
|
N/A |
1025 |
1488 |
1938 |
2065 |
2603 |
3880 |
4818 |
4' 0" |
|
|
|
|
|
|
1313 |
1783 |
1880 |
2393 |
3675 |
4503 |
4' 3" |
|
|
|
|
|
|
1215 |
1643 |
1698 |
2225 |
3303 |
4218 |
4' 6" |
|
|
|
|
|
|
N/A |
1488 |
1560 |
2098 |
3123 |
3958 |
4' 9" |
|
|
|
|
|
|
N/A |
1363 |
1450 |
1920 |
2918 |
3675 |
5' 0" |
|
|
|
|
|
|
N/A |
1270 |
N/A |
1785 |
2693 |
3415 |
5' 3" |
|
|
|
|
|
|
|
|
N/A |
1698 |
2523 |
3268 |
5' 6" |
|
|
|
|
|
|
|
|
N/A |
1520 |
2398 |
3088 |
5' 9" |
|
|
|
|
|
|
|
|
N/A |
1450 |
2150 |
2918 |
6' 0" |
|
|
|
|
|
|
|
|
|
|
2048 |
2715 |
6' 3" |
|
|
|
|
|
|
|
|
|
|
1878 |
2578 |
6' 6" |
|
|
|
|
|
|
|
|
|
|
N/A |
2398 |
6' 9" |
|
|
|
|
|
|
|
|
|
|
N/A |
2263 |
7' 0" |
|
|
|
|
|
|
|
|
|
|
N/A |
2150 |
7' 3" |
|
|
|
|
|
|
|
|
|
|
N/A |
2048 |
7' 6" |
|
Table reflects a safety
factor or 2:1 |
N/A |
1913 |
7' 9" |
|
COLORS
In addition to this standard
finish, tube, fitting and
accessories can be supplied with
polyester coating in any RAL
colour.
The polyester coating is highly
durable and is usually applied
to products that are already
galvanised. Should damage occur
to the coating ,Corrosion is
still prevented.
Typical examples of available
colours are shown on the pages
featuring the Fitpipe standard
range of fittings. Colours and
illustrative RAL references are
presented in the manner as shown
below.
|
|
 |
|
|
|
The Colours illustrated are for
general guidance only and
subject to normal variation
inherent in the printing
process.
|
|
|
|
|
|